AAI ORIGINAL English Verison N1201SA N1201SA+ 34.375MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester
109
Ua palekana ka uku

ʻAe ʻia nā mea hoʻihoʻi i loko o 40 lā mai ka lā loaʻa. ʻAʻole hiki ke hoʻihoʻi i nā mea i hoʻohui ʻia. ʻAʻole hiki ke hoʻihoʻi i nā mea i kūʻai ʻia me ka kāleka makana.
Makana Manuahi
Aloha mai i Roymall, kāu pūnaewele kūʻai makana maikaʻi. Mahalo nui mākou i kāu kākoʻo, a hāʻawi mākou i makana manuahi me kēlā me kēia kūʻai. Mākaukau e ʻimi i kā mākou hōʻiliʻili? E nānā i kā mākou koho, kau i kāu kauoha, a e kali no kāu makana manuahi me kāu kūʻai.Kuleana Hoʻouna
Hoʻoponopono mākou i nā kauoha i loko o 2 lā.ʻO ka manawa hoʻouna maʻamau he 5-7 lā hana.Hiki ke ʻokoʻa ka manawa hoʻouna ma muli o ke kahua.1. Kuleana Hoʻihoʻi
ʻAe mākou i nā mea i kūʻai ʻia mai roymall.com wale nō. ʻAʻole hiki ke hoʻihoʻi i nā makana manuahi. Pono e hoʻohana ʻole ʻia ka mea a i ʻole i loko o ka pūʻolo kumu.Hoʻoponopono mākou i nā hoʻihoʻi i loko o 3-5 lā hana ma hope o ka loaʻa.ʻAʻole hiki ke hoʻihoʻi i nā mea i hoʻohui ʻia.E kelepona iā mākou: service@roymall.com a i ʻole Whatsapp: +86193598494712.Kuleana Uku
E loaʻa iā ʻoe ka uku piha ma hope o ka loaʻa a me ka nānā ʻana. ʻAʻole hiki ke hoʻihoʻi i nā uku hoʻouna.E kelepona iā mākou: service@roymall.com a i ʻole Whatsapp: +8619359849471
Description:
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown:
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis
Specification:
working currency: 140MHz~2700MHz
stepped frequency: 1kHz
Display: 2.4inch TFT
resolution: 320*240(QVGA)
battery: 2000mAH(7.4Wh)
power consumption: <1.5W
charge current: 400mA
charge port: USB
Auto power off can be set 5-60minutes
Measured parameters:
resistence reactance standing wave s11
resolution ratio: 4 number
frequency accuracy: about 5ppm
Connector: SMA-K
Measurement range:
impedance: 0.1~1000
standing wave: 1.000~65
s11(dB): 0dB~-60dB
Working temperature: 0~40 degree
Package included:
1 x Original N1201SA Antenna Analyzer Meter
1 x English User Manual
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown:
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis
Specification:
working currency: 140MHz~2700MHz
stepped frequency: 1kHz
Display: 2.4inch TFT
resolution: 320*240(QVGA)
battery: 2000mAH(7.4Wh)
power consumption: <1.5W
charge current: 400mA
charge port: USB
Auto power off can be set 5-60minutes
Measured parameters:
resistence reactance standing wave s11
resolution ratio: 4 number
frequency accuracy: about 5ppm
Connector: SMA-K
Measurement range:
impedance: 0.1~1000
standing wave: 1.000~65
s11(dB): 0dB~-60dB
Working temperature: 0~40 degree
Package included:
1 x Original N1201SA Antenna Analyzer Meter
1 x English User Manual
Products related to this item
Loading related products...
❮
❯
Videos for similar product
Loading product videos...
❮
❯
Tools, Industrial & Scientific Ranking
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
Startup and shutdown:
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2, try to use good quality RF cable and connectors.
3, calibrated cable marked to the next may not need to calibrate and direct use.
4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis
Specification:
working currency: 140MHz~2700MHz
stepped frequency: 1kHz
Display: 2.4inch TFT
resolution: 320*240(QVGA)
battery: 2000mAH(7.4Wh)
power consumption: <1.5W
charge current: 400mA
charge port: USB
Auto power off can be set 5-60minutes
Measured parameters:
resistence reactance standing wave s11
resolution ratio: 4 number
frequency accuracy: about 5ppm
Connector: SMA-K
Measurement range:
impedance: 0.1~1000
standing wave: 1.000~65
s11(dB): 0dB~-60dB
Working temperature: 0~40 degree
Package included:
1 x Original N1201SA Antenna Analyzer Meter
1 x English User Manual